WinLog 2.0 History Build 049 - New Firmware V1.014 for MiniLog2 - Internal flash is now protected against random erases forced by low battery With a low battery the internal calibration of the MiniLog could be erased, this leads to continously wrong measurements because of lost calibration data. - 5 ms time delay added for coupon measurement - After a warmstart, most important settings are left unchanged - The PC Symbol flashes correctly with a USB connection -Timeline in graphic extended, 3 and 4 days are selectable -Standard deviation for "Off-Mean value" is calculated and shown in graphics and printout -In a printout with "Off-mean value" the changed statistic is named -Adjustment for the bootloader for the new firmware V.1014 -The sampling rate is shown in the printout -Reference for the expiration of the update service with a message and display of the date of expiration -Solved: -errors in the naming of the right Y-axis -false message to save the file due to changes in the print dialog which wasn't changed Build 048 -Threshold statistic in printout The percentage of below and above threshold for each channel is printed -Off-Mean value selectable period 24h added -Solved: -Excel- and Google Maps-Export of GPS coordinates (only English Windows) -optimized handling of file extension (*.WL2) -errors in print routine -translations added Build 047 -New MiniLog2 firmware 1.013: - 1ms sampling rate enabled. 1 kHz single channel sampling for 30 minutes maximum. Note: No display of values during sampling possible, as the sampling takes all the available processing power. - Coupon measurement with 1s enabled. Allows measuring of ON- and OFF-Potential, and DC and AC current for every second. Measurement can be done with "MiniCoup" adapter, or with an external shunt wiring. Preset of the measuring time after the switching available via key (PROG) for 10ms, 20ms, 50ms, 100ms oder 200ms. Display shows potential (On/Off) or current (DC/AC), this is changeable during sampling by key arrow "UP". - (DCVG) measurements without connected GPS antenna possible. Choose with key (MODE) "GPS On/Off" before (START). - (DCVG) during night hours with automatic activation of keyboard and display illumination. - During data logging illumination of display and keyboard via key press possible. - After warm start the (LOGGER) settings are no longer destroyed. - Night- and weekend savings (SLEEP) during active sampling corrected. - Display can be switched off with key (STOP), activation of the display by simple key press. - Communication problems even with PC-Symbol corrected -User defined limit line is not printed when value is zero -Samplings with 1ms activated -Excel-Export (Office 2007,2010) for samplings with 1ms is limited to 1 million values -Coupon sampling activated -Solved: -Problems with comments containing ";" -Problems with y-axis in printdialog -Errors with positions for Google Maps Build 046 - DCVG without GPS gets index as meter IMD-files contain the date of first value taken Solved: -possible problems with distance calculation in *.kml files -problems with showing the units -problems with the printout with Adobe PDF -problems with the logo -problems with printimng of "Off-Mean value" -Format of AC-values in the table corrected Build 045 - New firmware 1.012 for MiniLog2 to solve update problems in 1.011 Color definition in *.WL2 files are supported Activated "Off-Mean-Values" can be printout via "Print chart from screen" Build 044 - Bugfix Build 043 - User defined limit line in graphic printout New firmware 1.011 for MiniLog2 to solve keyboard problems Solved: -possible crashes when using moving average -problems with logo in quick print Build 042 - New Y-Axis assignment of the channels in printout For more than two channels and an active right y-axis the DC channels are assigned to the left side and the AC channels to the right Support for MiniCoup Correction of the min/max lines in the printout Changed formats in statistics DCVG: -support for Omnistar GPS antennas -reading of DCVG samplings with broken MiniLog2 identification possible Build 041 - Solved: -Communicationproblem during reading of Identification from MiniLog2 -Error in GPS-coordinates in Asia Improved accuracy/rounding when printing right y-axis Improved visualisation of marks (min, max, median) in printout Build 040 - Solved: -Error from Build 039: Programming the Identification is accessible again Build 039 - Mousezoom optimized Rework: -Communication with MiniLog2 Build 038 - Add new language: Romanian Solved: -possible wrong showing of memory use of samplings -problems reading MiniTrans datalogging Build 037 - Solved: -use of markers in table for "Erase section" -problems Google Maps export -problems reading DCVG -problems reading *.log files Build 036 - New firmware V1.009 for MiniLog2 - External button for the "FeatureConnector" simulates "OK" button press for DCVG - Fixed some minor errors Changed defect threshold evaluation Context menu (right mousebutton) added for "Erase marker" and zoom out functions Build 035 - Set minimum size for mousezoom Edit: -Google Maps support for printout Solved: -Errormessage when printing after reading of MiniLog Build 034 - Solved:-Error message when starting print setup -"Save as" dialog error -Excel-Export problems on foreign operating systems Build 033 - Reading DCVG from a MiniLog2 or IMD-files creates in addition Excel-files DCVG Excel export can be disabled Automatic upload of DCVG to Google Maps can be disabled Correctoin of GPS reading Solved: -Phantom lines in graphic -Offset and factor reading of old *.log files -statistic settings Build 032 - Programming the MiniLog 128/512 recording settings corrected for AC/AC and sampling rate Printpreview optimized for samplings > 7 days Zoom for X-Axis is up to 10ms Samplingrates with less 100ms are evaluable 120dpi scale for monitorfonts shows right proportion Samplings from start / to end can be deleted Build 031 - Sometimes the progressbar is not shown when reading MiniLog 128/512 samplings, error is fixed Build 030 - New firmware V1.007 for MiniLog2 - Protection against deep discharge during sampling - 4 times higher resolution for Range 'Lo' - optimized communication with WinLog 2.0 Automatic check for firmware update for MiniLog2 Detection of missing printer installation Check for compatibility between MiniLog2 firmware <=> WinLog 2.0 Build version Display state of charge at the end of a sampling Marking when battery was deep discharged during sampling Build 029 - QM-Data reformatted Print - statistic values are rounded more exactly - Date and timeformat changed Build 028 - Excel-Export in Toolbar activated Fileformat changed to manage deaktivated channels Dateformat changed i file Printsettings changed (Time and right Y-Axis) Error in median for right Y-axis solved Identification reading error MiniLog2 fixed Build 027 - Bugfix Build 026 - Correction for creating PDF-documents Error reading WinLog 1.3 files fixed Build 025 - Changes/Bugfix in printmenu Bugfix for saving files Build 024 - Corrected dataformat for CIPS/Gradient measurement Build 023 - Setup changed - Userfolder won't be created Printerrors solved (Time and Y-axis loading from file) Icons Build 022 - Updatecheck errors solved Region settings optimized Build 021 - New driver for MiniLog2 Build 020 - Upload of KML and download of updates via http Format of statisticvalues same as grid Surveilance monitor for MiniLog2 USB communication Build 019 - MiniLog2 reading of dataloggings aktivated Userinterfaces optimized Off-Mean Value-Function activated Format of values changed Bugfixes in printmenu Bugfixes Build 018 - Update improved Bugfixes Build 017 - DCVG-Measuring optimizied direct upload to Google Maps Upload of *.imd- und *.kml-files clock, battery und identification read and write for MiniLog2 check for updates for WinLog2 at programstart Update for MiniLog2 Firmware optimizied bugfix in *.WL2 timeformat Build 015 - New fileformat *.WL2 Build 011 - Implementation of loading DCVG measurements from ML2 creating *.kml-files for GoogleMaps/Earth Build 010 - Printpreview changes µV-Units Comments Commandelements changed Build 009 - Bugfixes Build 008 - Acceleration of printprocess Build 007 - Check for Updates Bugfixes(Mauszoom, Printdialog) Build 006 - MiniLog2 Connection Bugfixes Build 005 - Check for Updates Printdialog Bugfixes Build 004 - New setup Bugfixes Build 003 - Bugfixes Build 002 - Bugfixes Build 001 - First release