Technical Data MiniTrans

Technical Data for all types

Description: Battery operated wireless sensor for radio-controlled monitoring
and registration of CP-measuring data and for remote controlled
switching of rectifier station 
Measuring Inputs: 2 x DC (with high AC attenuation)
2 x AC (parallel to DC channel measuring)
1 x µV (with high AC attenuation) 
Memory: 32 KByte Program / 96 KByte Data 
Interface: 9600 Baud serial for programming and supervision on installation site 
Timer: DCF-77synchronised real time clock with supply voltage change-over
and active temperature compensation 
Timer Deviation: 50 ms max. at 12 DCF receiver sequences / day
(between -20°C and 60°C) 
Switching Load Output: 30 Volt / 0.1 Ampere / 30 Ω
(higher load with external power supply unit) 
Wireless system: Internal radio modem for GSM networks at 900 MHz 
Antenna: Special antenna combination for DCF and GSM-radio application for test point mounting or rectifier station installation 
Program Updates: Wireless via remote transmission or direct via serial interface 
Calibration control QM: Via serial interface with notebook on site 
Battery Power Supply: Lithium battery pack 7,2 V / 13 Ah
(uninterrupted data safety during battery change) 
Mains Power Supply (optional): External Power Supply Unit with slave relais control 
Dimension / Weight
Wireless Sensor
Antenna 
65 x 240 x 40 mm (W x H x D) / 480 g (incl. Battery)
75 x 60 x 40 mm (W x H x D) / 170 g (excl. Antenna rod) 

Remote Monitoring / Switching of Rectifier Station

Monitoring Facilities: 2 DC channels On / Off
(e.g. potential and protection tube)
2 AC channels
(e.g. potential and foreign pipe)
1 µV channel On / Off
(e.g. pipe current or rectifier current) 
Measuring periods:
Mode Normal

Mode Diagnosis 

Max. 4 complete on- and off- measurements / day
(timer freely programmable)
5, 10, 30, 60 or 120 min 
Formation of mean value: Freely programmable
(without or 1, 2, 4 or 8 min) 
Switching options:
Permanent On
Measuring Cycle
Permanent Cycle
Permanent Off 

e.g. in case of interface measurements
Standard setting at remote monitoring
e.g. 12/3 or 4/2 for intensive measurement
For pipe repair 
Radio periods:
Mode Normal

Mode Diagnosis 

Max. 4 complete on- and off- measurements / day
(timer freely programmable)
Every 5, 10, 30, 60, or 120 min 
Status Monitoring:
DCF-77 Signal
Synchronisation
Radio Signal
Battery State
Mains Power Supply
Temperature
Zero-Calibration 

Quality and reception successes
Timer deviation in ms
Quality and reception successes
Remaining capacity and operational time
Mains failure indicator
Temperature measurements
Monitoring measurements accuracy 
Remote programming: All settings and measuring features are completely remote programmable 
Battery Life Span:
Mode Normal
Radio on Weekends Off 

Approx. 2,5 to 3 years
Approx. 3,5 to 4 years 

Registration / Data Logger

Channels: 2 DC, 2 AC, 1 Microvolts 
Sampling Rate:
without microvolts measurements
with microvolts measurements 

0,5 s, 1 s, 2 s, 5 s, 10 s, 30 s
2 s, 5 s, 10 s, 30 s 
Measuring values memory: ca. 50,000 values 
Programing: Number of channels
Measuring range
Sampling rate
Start-up
Terminal time 
Data Transmission: Wireless by radio
or direct via serial interface 
Remote Programming: all features remote programmable 
Battery Life Span: Approx. 80 single channel recordings
at 1s sampling rate over 6 h
(incl. radio transmission) 
Zero Calibration: Automatic during registration 

Measuring Ranges / Resolution

DC Voltage (Channel1 und 2)

 Range Resolution 
 ± 1000 mV
± 10 V
± 150 V 
0,1 mV
1 mV
15 mV 
Input Impedance: > 2 MΩ  
Damping:
at 16,6 Hz
at 50,0 Hz 

60 dB (factor 1.000)
100 dB (factor 100.000) 
 

AC Voltage (Channel 1 und 2)

 Range Resolution 
  1 V eff.
10 V eff.
250 V eff. 
0,2 mV
2 mV
50 mV 
Input Impedance: > 2 MΩ  
Frequency Range: 15 Hz - 500 Hz  

Microvolts (Channel 3)

 Range Resolution 
 ± 100 mV 1 µV 
Input Impedance: > 200 KΩ  
Damping:
at 16,6 Hz
at 50,0 Hz 
60 dB (factor 1.000)
100 dB (factor 100.000) 
 
Zero Calibration: Automatic before measurement  

Weilekes elektronik